Fire Lite Alarms MS-9200UDLS

198 Point Intelligent Addressable Fire Alarm Control Panel

198 Point Intelligent Addressable Fire Alarm Control Panel, Listed to UL standard, On-board DACT, Selectable strobe synchronization, Remote Acknowledge, Detector sensitivity test.
List : $1,300.00  
Price : $1,058.81
Save :  $241.19
Qty :
 
Silent Knight 5104  
Silent Knight 5700  
Fire Lite Alarms MS-9050UD  
Slient Knight 5808  
Slient Knight 5820XL  
Fire Lite Alarms MS-9600LS  
Prev
Next
Contact our Experts!
877-926-2288
Ask a Question  about the Fire Lite Alarms MS-9200UDLS 198 Point Intelligent Addressable Fire Alarm Control Panel

Fire Lite Alarms MS-9200UDLS Intelligent Addressable FACP

 

The Fire Lite MS-9200UDLS Rev 2 with Version 4.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UDLS Rev 2 may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeed mode Fire Lite's latest polling technology for a quicker device response time. LiteSpeed's patented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With Litespeed polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The MS-9200UDLS Rev 2s quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. Available accessories include ANN BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/ city box transmitter. The integral DACT transmits system status (alarms, supervisories, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network. Any personal computer with Windows XP or greater, a compatible modem, and PS-Tools, the Fire Lite Upload/Download  software kit, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 4.0 firmware supports the following: ANN-bus devices, AD355 (LiteSpeed), USB port, NAC circuit diagnostics, a new report has been added to the walk-test that lists untested devices, new device types added: audio telephone type code for ACC 25/50ZST, Photo Supervisory and auto-resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line.

 

Features

 

  • Listed to UL standard 864, 9th edition.
  • On-board DACT.
  • Remote site or local USB port upload/download, using PSTools.
  • Four Style Y (Class B) or two Class A (Style Z) NAC circuits. (Up to 6.0 amps total NAC power when using optional XRM-24B.)
  • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices.
  • Remote Acknowledge, Silence, Reset and Drill via addressable monitor modules or LCD-80F, ANN-80 or ACS Annunciators.
  • ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used
  • EIA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6F.
  • Integral 80-character LCD display with backlighting.
  • Real-time clock/calendar with automatic daylight savings
  • control.
  • Detector sensitivity test capability (NFPA 72 compliant).
  • History file with 1,000-event capacity.
  • Maintenance alert warns when smoke detector dust accumulation is excessive.
  • Automatic device type-code verification.
  • One person audible or silent walk test with walk-test log and printout.
  • Point trouble identification.
  • Waterflow (nonsilenceable) selection per monitor point.
  • System alarm verification selection per detector point.
  • PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant).